top of page

Data Center and Facility 3 Phase UPS

APC Uniflair LE
Symmetra 20/40/100

High performance, right-sized, modular, scalable, 3 phase UPS power protection with ultra high availability and 94% -95% efficiency.

Characteristics

  • Power Rating: 10 to 100KW in 10Kw increments

  • Output Power Factor: 1

  • Input: 208V 3 phase +N + G

  • Output: 208 3 phase + N + G or 3P + G

  • Batter: VRLA

​

​

Application

  • Data Closets

  • High Denisty Zones

  • Small and Medium Data Centers

​

Smart UPS VT

Effective 3 phase UPS power protection against downtime and data loss for mission critical applications.

Characteristics

  • Power Rating: 10/15/20/30 kVa

  • Output Power Factor: 0.8

  • Input: 208 -220 V 3(3ph +N +G)

  • Output 200 -220 V 3(3ph +N +G)

  • Batter: Integrated, maintenance-free, sealed lead acid

​

​

Application

  • Small Data Centers

  • Medical Server Rooms

  • Laboratories

  • Point Of Sale

  • Government and Institutional

​

Galaxy 3500

Compact 3 phase UPS power protection with excellent efficiency and optimized footprint particularly adapted for demanding industrial environments.

Characteristics

  • Power Rating: 10/15/20/30 kVa

  • Output Power Factor: 0.8

  • Input: 208 - 220 V 3(3ph +N +G)

  • Output: 208V

  • Batter: Integrated, maintenance-free, sealed lead acid

​

​

Application

  • Telecom Ceneters

  • Commercial Building

  • Transporation and Infrastructures

  • Technical Facilities

  • Industrial Plants and Process Protection

​

Galaxy 4000

Robust 3 phase UPS power protection designed to meet a wide range of requirements from medium data centers to industrial and facilities applications

Characteristics

  • Power Rating: 45/50/65/75 kVa

  • Output Power Factor: 0.8

  • Input: 208V 3 Phase

  • Output: 208V 3 Phase

  • Batter: Adjacent, remote, VRLA, wet cell

​

​

Application

  • Mission-critical Environments

  • Small to Medium Data Centers

  • Telecom Centers

  • Industrial Plants 

​

Galaxy 5000

Three phase UPS power protection designed to meet a wide range of requirements from medium data centers to industrial and facilities applications

Characteristics

  • Power Rating: 40/50/60/80/100 kVa

  • Output Power Factor: 0.9

  • Parallell Capacity: Up to 6 units for capacity or redundancy

  • Input: 480V (208V and 600V with Transformer

  • Output: 480V (208V and 600V with Transformer

  • Batter: Integrated, adjacent, remote, open rack, VRLAl

​

​

Application

  • Mission-critical Environments

  • Medium Data Centers

  • Telecom Centers

  • Industrial Plants 

​

Galaxy VM

Highly 3 phase UPS power protection that seamlessly integrates into medium data centers, industrial or facilities applications.

Characteristics

  • Power Rating: 160/180/225 kVa

  • Output Power Factor: 0.9

  • Parallell Capacity: Up to 4 units for capacity, 5 for redundancy

  • Input: 480V (208 V with Transformer

  • Output: 480V (208 Vwith Transformer

  • Batter: VRLA, Li-ion

​

Application

  • Mission-critical Environments

  • Small to Medium Data Centers

  • Facility Infrastructure

  • Industrial Plants 

​

Symmetra PX 250/500 KW

High performance, right-sized, modular, scalable, 3 phase UPS power protection with ultra high availability and efficiency

Characteristics

  • Power Rating: One UPS: 50 kVA to 500 kVA, in 25 kVA increments 
    Fully populated parallel system: 50 kVA to 2 MVA, in 25 kVA increments

  • Output Power Factor: 1

  • Parallell Capacity: Up to 4 units for capacity or redundancy

  • Input: 480V , 3 Phase +N +G

  • Output: 480V , 3 Phase +N +G

  • Batter: VRLA

​

Application

  • Mission-critical Environments

  • Medium to Large Data Centers

​

EPS 7000

Three phase UPS power protection and high adaptability makes the MGE EPS 7000 a facility managers top choice UPS

Characteristics

  • Power Rating: 300/400/500 kVA

  • Output Power Factor: 0.9

  • Parallell Capacity: Yes

  • Input: 480V or 600V , 3 Phase 

  • Output: 480V or 600V

  • Batter: Lead acid batteries (vented, sealed), NiCad

​

Application

  • Mission-critical Environments

  • Medium to Large Data Centers

  • Industrial Plants

​

EPS 8000

Three phase UPS power protection UPS systems with adaptability to meet the unique requirements of medium to large data centers, buildings and critical industrial processes

Characteristics

  • Power Rating: 555/625/750/800/1100/ 1125 kVA

  • Output Power Factor: 555 – 800 kVA (480/600 V), 1000 – 1100 kVA (480 V): 0.9 1000 – 1100 kVA (575/600 V), 1125 kVA (480/575/600 V):1.0

  • Parallell Capacity: Up to 6 Modules    (1,100 kVA)

  • Input: 80, 575, or 600 V, three-phase

  • Output: 555 - 800 kVA: 480 or 600 V; 1000 - 1125 kVA: 480, 575, or 600 V

  • Batter:  Lead acid batteries (vented, sealed), NiCad

​

Application

  • Mission-critical Environments

  • Large Data Centers

  • Industrial Facilities

​

​

Galaxy VX

Highly efficient, scalable, 3-phase power protection with flexible operating modes, for large facilities, data centers, and business critical applications.

Characteristics

  • Power Rating: 500/625/750 kVA (480 V); 1000/1250/1500 kVA N+1 (480 V)

  • Input Power Factor: 99% @ >40% Load

  • Output Power Rating: 1.0 kVA = kW

  • Parallell Capacity: 00 – 750 kVA: Up to 4 + 1 (4 units for capacity + 1 for redundancy);  1250/1500 kVA: Up to 3 UPS units in N+1 configuration, where N is 2, 1 for redundancy; Up to 2 UPS units for capacity

  • Input: 4880 V +20%/-15% @ 100% load, 3 wire + G

  • Output: 480 V, 3-wire (3PH + G)

  • Batter: VRLA, Flooded, Li-ion

​

Application

  • Mission-critical Environments

  • Large to Extra Large Data Centers

  • Facility Infrastructure

  • Colocation Facilities

  • Finance, Semicondustor and Manufacturing Envirnments

​

Symmetra Megawatt

Ultra energy efficient, modular, scalable, 3 phase UPS power protection with industry-leading performance for large data centers and mission-critical environments

Characteristics

  • Power Rating: One UPS: 400 – 1,600 kVA, scalable in 200 kVA increments Parallel system: 400 kW – 6.4 MW, in 200 kW increments

  • Output Power Factor: Unity

  • Parallell Capacity: Up to 4 UPSs for 6.4 MW of capacity or redundancy

  • Input: 208V , 3 Phase +N +G

  • Output: 120/208V , 3 Phase +N +G

  • Batter: VRLA

​

Application

  • Mission-critical Environments

  • Medium to Large Data Centers

  • Colocation Facilities

  • Finance, Semicondustor and Manufacturing Envirnments

​

bottom of page