Data Center and Facility 3 Phase UPS
Symmetra 20/40/100
High performance, right-sized, modular, scalable, 3 phase UPS power protection with ultra high availability and 94% -95% efficiency.
Characteristics
-
Power Rating: 10 to 100KW in 10Kw increments
-
Output Power Factor: 1
-
Input: 208V 3 phase +N + G
-
Output: 208 3 phase + N + G or 3P + G
-
Batter: VRLA
Application
-
Data Closets
-
High Denisty Zones
-
Small and Medium Data Centers
Smart UPS VT
Effective 3 phase UPS power protection against downtime and data loss for mission critical applications.
Characteristics
-
Power Rating: 10/15/20/30 kVa
-
Output Power Factor: 0.8
-
Input: 208 -220 V 3(3ph +N +G)
-
Output 200 -220 V 3(3ph +N +G)
-
Batter: Integrated, maintenance-free, sealed lead acid
Application
-
Small Data Centers
-
Medical Server Rooms
-
Laboratories
-
Point Of Sale
-
Government and Institutional
Galaxy 3500
Compact 3 phase UPS power protection with excellent efficiency and optimized footprint particularly adapted for demanding industrial environments.
Characteristics
-
Power Rating: 10/15/20/30 kVa
-
Output Power Factor: 0.8
-
Input: 208 - 220 V 3(3ph +N +G)
-
Output: 208V
-
Batter: Integrated, maintenance-free, sealed lead acid
Application
-
Telecom Ceneters
-
Commercial Building
-
Transporation and Infrastructures
-
Technical Facilities
-
Industrial Plants and Process Protection
Galaxy 4000
Robust 3 phase UPS power protection designed to meet a wide range of requirements from medium data centers to industrial and facilities applications
Characteristics
-
Power Rating: 45/50/65/75 kVa
-
Output Power Factor: 0.8
-
Input: 208V 3 Phase
-
Output: 208V 3 Phase
-
Batter: Adjacent, remote, VRLA, wet cell
Application
-
Mission-critical Environments
-
Small to Medium Data Centers
-
Telecom Centers
-
Industrial Plants
Galaxy 5000
Three phase UPS power protection designed to meet a wide range of requirements from medium data centers to industrial and facilities applications
Characteristics
-
Power Rating: 40/50/60/80/100 kVa
-
Output Power Factor: 0.9
-
Parallell Capacity: Up to 6 units for capacity or redundancy
-
Input: 480V (208V and 600V with Transformer
-
Output: 480V (208V and 600V with Transformer
-
Batter: Integrated, adjacent, remote, open rack, VRLAl
Application
-
Mission-critical Environments
-
Medium Data Centers
-
Telecom Centers
-
Industrial Plants
Galaxy VM
Highly 3 phase UPS power protection that seamlessly integrates into medium data centers, industrial or facilities applications.
Characteristics
-
Power Rating: 160/180/225 kVa
-
Output Power Factor: 0.9
-
Parallell Capacity: Up to 4 units for capacity, 5 for redundancy
-
Input: 480V (208 V with Transformer
-
Output: 480V (208 Vwith Transformer
-
Batter: VRLA, Li-ion
Application
-
Mission-critical Environments
-
Small to Medium Data Centers
-
Facility Infrastructure
-
Industrial Plants
Symmetra PX 250/500 KW
High performance, right-sized, modular, scalable, 3 phase UPS power protection with ultra high availability and efficiency
Characteristics
-
Power Rating: One UPS: 50 kVA to 500 kVA, in 25 kVA increments
Fully populated parallel system: 50 kVA to 2 MVA, in 25 kVA increments -
Output Power Factor: 1
-
Parallell Capacity: Up to 4 units for capacity or redundancy
-
Input: 480V , 3 Phase +N +G
-
Output: 480V , 3 Phase +N +G
-
Batter: VRLA
Application
-
Mission-critical Environments
-
Medium to Large Data Centers
EPS 7000
Three phase UPS power protection and high adaptability makes the MGE EPS 7000 a facility managers top choice UPS
Characteristics
-
Power Rating: 300/400/500 kVA
-
Output Power Factor: 0.9
-
Parallell Capacity: Yes
-
Input: 480V or 600V , 3 Phase
-
Output: 480V or 600V
-
Batter: Lead acid batteries (vented, sealed), NiCad
Application
-
Mission-critical Environments
-
Medium to Large Data Centers
-
Industrial Plants
EPS 8000
Three phase UPS power protection UPS systems with adaptability to meet the unique requirements of medium to large data centers, buildings and critical industrial processes
Characteristics
-
Power Rating: 555/625/750/800/1100/ 1125 kVA
-
Output Power Factor: 555 – 800 kVA (480/600 V), 1000 – 1100 kVA (480 V): 0.9 1000 – 1100 kVA (575/600 V), 1125 kVA (480/575/600 V):1.0
-
Parallell Capacity: Up to 6 Modules (1,100 kVA)
-
Input: 80, 575, or 600 V, three-phase
-
Output: 555 - 800 kVA: 480 or 600 V; 1000 - 1125 kVA: 480, 575, or 600 V
-
Batter: Lead acid batteries (vented, sealed), NiCad
Application
-
Mission-critical Environments
-
Large Data Centers
-
Industrial Facilities
Galaxy VX
Highly efficient, scalable, 3-phase power protection with flexible operating modes, for large facilities, data centers, and business critical applications.
Characteristics
-
Power Rating: 500/625/750 kVA (480 V); 1000/1250/1500 kVA N+1 (480 V)
-
Input Power Factor: 99% @ >40% Load
-
Output Power Rating: 1.0 kVA = kW
-
Parallell Capacity: 00 – 750 kVA: Up to 4 + 1 (4 units for capacity + 1 for redundancy); 1250/1500 kVA: Up to 3 UPS units in N+1 configuration, where N is 2, 1 for redundancy; Up to 2 UPS units for capacity
-
Input: 4880 V +20%/-15% @ 100% load, 3 wire + G
-
Output: 480 V, 3-wire (3PH + G)
-
Batter: VRLA, Flooded, Li-ion
Application
-
Mission-critical Environments
-
Large to Extra Large Data Centers
-
Facility Infrastructure
-
Colocation Facilities
-
Finance, Semicondustor and Manufacturing Envirnments
Symmetra Megawatt
Ultra energy efficient, modular, scalable, 3 phase UPS power protection with industry-leading performance for large data centers and mission-critical environments
Characteristics
-
Power Rating: One UPS: 400 – 1,600 kVA, scalable in 200 kVA increments Parallel system: 400 kW – 6.4 MW, in 200 kW increments
-
Output Power Factor: Unity
-
Parallell Capacity: Up to 4 UPSs for 6.4 MW of capacity or redundancy
-
Input: 208V , 3 Phase +N +G
-
Output: 120/208V , 3 Phase +N +G
-
Batter: VRLA
Application
-
Mission-critical Environments
-
Medium to Large Data Centers
-
Colocation Facilities
-
Finance, Semicondustor and Manufacturing Envirnments