Power Distribution
Rack Power Distribution
Rack PDUs provide server level power availability with a variety of power metering and control options as well as environmental monitoring capability.
​
Metered-by-Outlet w/Switching Rack PDU
Provides real-time remote monitoring of each individual outlet combined with remote on/off switching control of individual outlets.
​
Switched Rack PDU
Provide advanced load monitoring combined with remote on/off switching control of individual outlets for power cycling, delayed power sequencing, and outlet use management.
​
Metered Rack PDU
Provides real-time remote monitoring of connected loads. User-defined alarms warn of potential circuit overloads before critical IT failures occur.
​
Basic Rack PDU
Provides reliable rack power distribution via a single input with multiple output receptacles and distributes power from low amperage single phase circuits to higher-power 3-phase solutions.
​
Metered-by-Outlet Rack PDU
Provide real-time remote monitoring of each individual outlet to empower IT professionals with the necessary tools for advanced data center energy management.
​
myNetShelter PDUs
Customized or completely new rack PDUs allowing data centers to streamline customization and avoid costly, unsafe field modifications using unique colors, input cord plugs and outlet configurations done simply and delivered to specification.
​
Three Phase Row and Room
Modular Power Distribution
Agile, safe, efficient power distribution system for IT equipment in any size data center or high density zone
​
-
Minimal, white space footprint
-
Truly safe with hot-scalable modules
-
Toolless expansion
-
Easy integration with InfraStruxure solutions
-
Pre-configured breakers and cord-sets for ease of deployment
-
Fully compliant, global offering
-
72/144/266/277 kW
​
Configurable Power Distribution
Configured to order, factory assembled power distribution units for IT equipment in any size data center or high density zone bringing agility, availability, and speed of deployment to your data center
​
-
Configured to order
-
Factory assembled for high quality
-
Easy integration with InfraStruxure solutions
-
Pre-configured cord sets
-
40 – 150 kW PDU,10U RPP
​
Room Power Distribution
Centralized 3 phase power distribution adaptable to the needs of any size data center with integrated isolation, electronic-grade grounding, and distribution for up 252 output breakers.
​
-
Customized and factory assembled for high quality
-
Customers are experienced with the form factor
-
Easily expandable using Remote Power Management Modules
-
30 to 300 kVA
​
Rack Mount Transfer Switches
-
Eliminate the need for a secondary rack PDU downstream
-
Automatic switching power redundancy to single corded equipment
-
Effective solution for maintenance bypass needs
-
Continuous source monitoring
-
Robust out-of-phase switching capability
-
Typical switching time of 8-12ms; 16ms max @ 60 Hz, 18ms max @ 50Hz
-
120/200/208/230V; 15 to 30 A Input Feed
​
Static Trasnfer Switches
-
Simplifies installation and maintenance, while minimizing space requirements.
-
Independent control boards and dua lcooling systems and power supplies
ensure high reliability performance. -
Text and mimic diagrams that display modes of operation, system parametersand alarms.
-
Allows isolation of a source for maintenance,without interrupting power to the protected loads.
-
Small footprint reduces required floor space
-
208, 220, 240, 480, 575,600 V 3 Phase
-
200/400/600 A